CANLI
Yükleniyor Veriler getiriliyor…
SCI-Expanded Özgün Makale Scopus 🌍 Uluslararası
The effects of image compression on quantitative measurements of digital panoramic radiographs
Medicina Oral Patología Oral y Cirugia Bucal 2012 Cilt 17
Scopus Eşleşmesi Bulundu
19
Atıf
17
Cilt
e1074-e1081
Sayfa
🔓
Açık Erişim
Özet
Objectives: The aims of this study were to explore how image compression affects density, fractal dimension, linear and angular measurements on digital panoramic images and assess inter and intra-observer repeatability of these measurements. Study Design: Sixty-one digital panoramic images in TIFF format (Tagged Image File Format) were compressed to JPEG (Joint Photographic Experts Group) images. Two observers measured gonial angle, antegonial angle, mandibular cortical width, coronal pulp width of maxillary and mandibular first molar, tooth length of maxillary and mandibular first molar on the left side of these images twice. Fractal dimension of the selected regions of interests were calculated and the density of each panoramic radiograph as a whole were also measured on TIFF and JPEG compressed images. Intra-observer and inter-observer consistency was evaluated with Cronbach's alpha. Paired samples t-test and Kolmogorov-Smirnov test was used to evaluate the difference between the measurements of TIFF and JPEG compressed images. Results: The repeatability of angular measurements had the highest Cronbach's alpha value (0.997). There was statistically significant difference for both of the observers in mandibular cortical width (MCW) measurements (1st ob. p: 0.002; 2nd ob. p: 0.003), density (p<0.001) and fractal dimension (p<0.001) between TIFF and JPEG images. There was statistically significant difference for the first observer in antegonial angle (1st ob p< 0.001) and maxillary molar coronal pulp width (1st ob. p< 0.001) between JPEG and TIFF files. Conclusions: The repeatability of angular measurements is better than linear measurements. Mandibular cortical width, fractal dimension and density are affected from compression. Observer dependent factors might also cause statistically significant differences between the measurements in TIFF and JPEG images.
Web of Science Eşleşmesi Bulundu
12
WoS Atıf
17
Cilt
Article
Belge Türü
Kaynak: MEDICINA ORAL PATOLOGIA ORAL Y CIRUGIA BUCAL · s. E1074-E1081
Anahtar Kelimeler (WoS)

Havuzumuzdaki Atıflar 0

Bu makaleye, sistemimizdeki Scopus veritabanında bulunan 0 makale atıf yapmıştır. Scopus genel atıf sayısı: 19.

Bu makaleye, kendi Scopus havuzumuzdaki başka bir makaleden atıf kaydı bulunmuyor.
Scimago Dergi Bilgisi Otomatik ISSN Eşleştirmesi 2012 yılı verileri
Medicina Oral Patologia Oral y Cirugia Bucal
Q1
SJR Quartile
0,613
SJR Skoru
77
H-Index
🔓
Açık Erişim
Kategoriler: Dentistry (miscellaneous) (Q1) · Medicine (miscellaneous) (Q2) · Otorhinolaryngology (Q2) · Surgery (Q2)
Alanlar: Dentistry · Medicine
Ülke: Spain · Medicina Oral S.L.
Bu bilgiler makale yılına göre Scimago veritabanından ISSN eşleştirmesiyle otomatik getirilmektedir. Dergi sıralama verileri Scimago'nun ilgili yılı baz alınmaktadır.

Anahtar Kelimeler

WoS | Bir kelimeye tıklayıp ilgili kaynaktaki yayınları görün.

Makale Bilgileri

Dergi Medicina Oral Patología Oral y Cirugia Bucal
ISSN 16986946
Yıl 2012 / 1. ay
Cilt / Sayı 17
Sayfalar 1074 – 1081
Makale Türü Özgün Makale
Hakemlik Hakemli
Endeks SCI-Expanded
Yayın Dili İngilizce
Ülke İSPANYA Uluslararası
Şehir Valencia
Kapsam Uluslararası
Toplam Yazar 3 kişi
Erişim Türü Elektronik
Alan Sağlık Bilimleri Temel Alanı- DİŞ HEKİMLİĞİ

YÖKSİS Yazar Kaydı

Yazar Adı YAŞAR FÜSUN,Apaydın Burcu,Yılmaz Hasan Hüseyin
YÖKSİS ID 2236674

Metrikler

Scopus Atıf 19
Havuz Atıfları 0
Yazar Sayısı 3