CANLI
Yükleniyor Veriler getiriliyor…
SCI Özgün Makale Scopus
Efficacy of Frequency Doubling Technology Perimetry in Non arteritic Anterior Ischaemic Optic Neuropathy with Altitudinal Visual Field Defects
NEURO-OPHTHALMOLOGY 2012 Cilt 36 Sayı 4
Scopus Eşleşmesi Bulundu
0
Atıf
36
Cilt
129-132
Sayfa
Özet
The aim of the study was to evaluate the ability of frequency doubling technology perimetry to detect altitudinal hemifield defects in cases of non-arteritic anterior ischaemic optic neuropathy. Thirty eyes of 24 cases of the disorder with typical altitudinal visual field defects underwent standard automated (Humphrey 24-2) and frequency doubling technology (N-30 threshold) perimetry. For both techniques locations showing a defect of p < 5% were considered abnormal and the mean percentage defect of both the involved and uninvolved hemifields and global visual field parameters were compared. The mean percentage defects for the involved and uninvolved hemifields were comparable (p = 0.1 and p = 0.07, respectively) but there were statistically significant differences in fixation losses and in test duration (p < 0.001 and p < 0.001, respectively) for the two techniques. The authors conclude that frequency doubling technology perimetry is reliable and easily performed in patients with altitudinal visual field defects. The similarity of the extent of visual field defects found using the two techniques suggests that frequency doubling technology perimetry can be used for the rapid detection of altitudinal defects in anterior ischaemic optic neuropathy. © 2012 Informa Healthcare USA, Inc.
Web of Science Eşleşmesi Bulundu
0
WoS Atıf
36
Cilt
Article
Belge Türü
Kaynak: NEURO-OPHTHALMOLOGY · s. 129-132
Anahtar Kelimeler (WoS)

Havuzumuzdaki Atıflar 0

Bu makaleye, sistemimizdeki Scopus veritabanında bulunan 0 makale atıf yapmıştır.

Bu makaleye, kendi Scopus havuzumuzdaki başka bir makaleden atıf kaydı bulunmuyor.
Scimago Dergi Bilgisi Otomatik ISSN Eşleştirmesi 2012 yılı verileri
Neuro-Ophthalmology
Q4
SJR Quartile
0,133
SJR Skoru
29
H-Index
Kategoriler: Neurology (clinical) (Q4) · Ophthalmology (Q4)
Alanlar: Medicine
Ülke: United Kingdom · Taylor and Francis Ltd.
Bu bilgiler makale yılına göre Scimago veritabanından ISSN eşleştirmesiyle otomatik getirilmektedir. Dergi sıralama verileri Scimago'nun ilgili yılı baz alınmaktadır.

Makale Bilgileri

Dergi NEURO-OPHTHALMOLOGY
ISSN 0165-8107
Yıl 2012 / 8. ay
Cilt / Sayı 36 / 4
Sayfalar 129 – 132
Makale Türü Özgün Makale
Hakemlik Hakemli
Endeks SCI
Yayın Dili İngilizce
Kapsam Uluslararası
Toplam Yazar 4 kişi
Alan Sağlık Bilimleri Temel Alanı- Göz Hastalıkları

YÖKSİS Yazar Kaydı

Yazar Adı Berker Bakbak, Şansal Gedik, Bengü Ekinci Köktekir, Nimet Yapıcı Pehlivan

Metrikler

Havuz Atıfları 0
Yazar Sayısı 4