CANLI
Yükleniyor Veriler getiriliyor…
SCI-Expanded Özgün Makale Scopus
Is a Neutral Head Position as Effective as Head Rotation During Landmark Guided Internal Jugular Vein Cannulation Results of a Randomized Controlled Clinical Trial
Journal of Cardiothoracic and Vascular Anesthesia 2012 Cilt 26 Sayı 6
Scopus Eşleşmesi Bulundu
11
Atıf
26
Cilt
985-988
Sayfa
Özet
Objective: Central venous access remains a cornerstone procedure for a variety of clinical conditions. Ultrasound studies suggest that rotation of the head increases the magnitude of the overlap of the internal jugular vein with the carotid artery. The authors assessed whether a neutral position of the head during anatomic landmark-guided cannulation of the internal jugular vein (IJV) was an attractive alternative to rotating the neck to a >45° head turn. Design: A prospective, randomized, controlled study. Setting: An education and research hospital and a university-affiliated hospital. Participants: Eighty patients requiring central venous catheterization in the right IJV. Interventions: Under general anesthesia, patients were positioned in the Trendelenburg position with extension of the neck. In the rotated group, the head was rotated to the left at >45°. In the neutral group, the head was placed in the neutral position. Right IJV cannulation was performed using the central approach with the needle angled toward the ipsilateral nipple. The primary outcome variable was the cumulative success rate, which was defined as IJV puncture achieved in the first 3 attempts using a finder needle. A p value of <0.05 was considered statistically significant. Measurements and Main Results: Groups were similar in terms of demographic data. The success rates of finder needle passes into the IJV on the first attempt were 87.5% and 37.5% (p < 0.05), and the cumulative success rates on the first 3 attempts were 97.5% and 57.5% in the rotated and neutral groups, respectively (p < 0.05). Carotid artery puncture only occurred in 2 patients in the rotated group. Conclusions: Because of the lower success rate, the neutral head position is not an attractive alternative for IJV catheterization when compared with the rotated head position in a central landmark IJV approach. © 2012 Elsevier Inc.
Web of Science Eşleşmesi Bulundu
7
WoS Atıf
26
Cilt
Article
Belge Türü
Kaynak: JOURNAL OF CARDIOTHORACIC AND VASCULAR ANESTHESIA · s. 985-988
Anahtar Kelimeler (WoS)

Havuzumuzdaki Atıflar 0

Bu makaleye, sistemimizdeki Scopus veritabanında bulunan 0 makale atıf yapmıştır. Scopus genel atıf sayısı: 11.

Bu makaleye, kendi Scopus havuzumuzdaki başka bir makaleden atıf kaydı bulunmuyor.
Scimago Dergi Bilgisi Otomatik ISSN Eşleştirmesi 2012 yılı verileri
Journal of Cardiothoracic and Vascular Anesthesia
Q1
SJR Quartile
0,747
SJR Skoru
100
H-Index
Kategoriler: Anesthesiology and Pain Medicine (Q1) · Cardiology and Cardiovascular Medicine (Q2)
Alanlar: Medicine
Ülke: United States · W.B. Saunders
Bu bilgiler makale yılına göre Scimago veritabanından ISSN eşleştirmesiyle otomatik getirilmektedir. Dergi sıralama verileri Scimago'nun ilgili yılı baz alınmaktadır.

Anahtar Kelimeler

WoS | Bir kelimeye tıklayıp ilgili kaynaktaki yayınları görün.

Makale Bilgileri

Dergi Journal of Cardiothoracic and Vascular Anesthesia
ISSN 10530770
Yıl 2012 / 12. ay
Cilt / Sayı 26 / 6
Sayfalar 985 – 988
Makale Türü Özgün Makale
Hakemlik Hakemli
Endeks SCI-Expanded
Yayın Dili İngilizce
Kapsam Uluslararası
Toplam Yazar 6 kişi
Erişim Türü Basılı+Elektronik
Alan Sağlık Bilimleri Temel Alanı- Anesteziyoloji ve Reanimasyon

YÖKSİS Yazar Kaydı

Yazar Adı APİLİOĞULLARI BURHAN,KARA İNCİ,APİLİOĞULLARI SEZA,ARUN OĞUZHAN,Saltali Ali,ÇELİK JALE BENGİ
YÖKSİS ID 584191

Metrikler

Scopus Atıf 11
Havuz Atıfları 0
Yazar Sayısı 6