CANLI
Yükleniyor Veriler getiriliyor…
SCI-Expanded Özgün Makale Scopus
The Effectiveness Of Trendelenburg Positioning On The Cross Sectional Area Of The Right Internal Jugular Vein In Obese Patients
Pakistan Journal of Medical Sciences 2015 Cilt 31 Sayı 4
Scopus Eşleşmesi Bulundu
12
Atıf
31
Cilt
770-774
Sayfa
🔓
Açık Erişim
Özet
Objective: Trendelenburg positioning is a common approach used during internal jugular vein (IJV) cannulation. No evidence indicates that Trendelenburg positioning significantly increases the crosssectional area (CSA) of the IJV in obese patients. The primary aim of this study was to determine the effectiveness of Trendelenburg positioning on the CSA of the right internal jugular vein assessed with ultrasound measurement in obese patients. Methods: Forty American Society of Anesthesiologists II patients with body mass index ≥30 kg/m<sup>2</sup> undergoing various elective surgeries under general endotracheal anesthesia were enrolled. Ultrasound images of the right IJV were obtained in a transverse orientation at the cricoid level. We measured the CSA of the right IJV two different conditions in a sealed envelope were applied in random order: State 0, table flat (no tilt), with the patients in the supine position, and State T, in which the operating table was tilted 20° to the Trendelenburg position. Results: The change in the CSA of the IJV from the supine to the Trendelenburg position (1.80 cm<sup>2</sup> vs 2.08cm<sup>2</sup>) was not significantly different. The CSA was paradoxically decreased in 10 of 36 patients when the position changed from State 0 to State T. Conclusions: Trendelenburg positioning does not significantly increase the mean CSA of the right IJV in obese patients. In fact, in some patients, this position decreases the CSA. The use of the Trendelenburg position for IJV cannulation in obese patients can no longer be supported.
Web of Science Eşleşmesi Bulundu
13
WoS Atıf
31
Cilt
Article
Belge Türü
Kaynak: PAKISTAN JOURNAL OF MEDICAL SCIENCES · s. 770-774
Anahtar Kelimeler (WoS)

Havuzumuzdaki Atıflar 0

Bu makaleye, sistemimizdeki Scopus veritabanında bulunan 0 makale atıf yapmıştır. Scopus genel atıf sayısı: 12.

Bu makaleye, kendi Scopus havuzumuzdaki başka bir makaleden atıf kaydı bulunmuyor.
Scimago Dergi Bilgisi Otomatik ISSN Eşleştirmesi 2015 yılı verileri
Pakistan Journal of Medical Sciences
Q3
SJR Quartile
0,206
SJR Skoru
53
H-Index
🔓
Açık Erişim
Kategoriler: Medicine (miscellaneous) (Q3)
Alanlar: Medicine
Ülke: Pakistan · Professional Medical Publications
Bu bilgiler makale yılına göre Scimago veritabanından ISSN eşleştirmesiyle otomatik getirilmektedir. Dergi sıralama verileri Scimago'nun ilgili yılı baz alınmaktadır.

Anahtar Kelimeler

WoS | Bir kelimeye tıklayıp ilgili kaynaktaki yayınları görün.

Makale Bilgileri

Dergi Pakistan Journal of Medical Sciences
ISSN 1681-715X
Yıl 2015 / 12. ay
Cilt / Sayı 31 / 4
Makale Türü Özgün Makale
Hakemlik Hakemli
Endeks SCI-Expanded
Teşvik Puanı 10,80 · YÖKSİS Akademik Teşvik
Yayın Dili İngilizce
Kapsam Uluslararası
Toplam Yazar 6 kişi
Erişim Türü Elektronik
Alan Sağlık Bilimleri Temel Alanı- Anesteziyoloji ve Reanimasyon

YÖKSİS Yazar Kaydı

Yazar Adı ÖNAL İBRAHİM ÖZKAN,APİLİOĞULLARI SEZA,NAYMAN ALAADDİN,saltalı Ali,YILMAZ HÜSEYİN,ÇELİK JALE BENGİ
YÖKSİS ID 577866

Metrikler

Scopus Atıf 12
Havuz Atıfları 0
Teşvik Puanı 10,80
Yazar Sayısı 6