Scopus Eşleşmesi Bulundu
32
Atıf
48
Cilt
919-922
Sayfa
Özet
Objectives: Laboratories determine the most appropriate approach for the collection and transport of urine specimens. We investigated the effect of a chlorhexidine-based preservative tube on sample stability, compared the results of refrigerated polystyrene tubes with no additives, and investigated the effect of temperature on the performance of preservative tubes. Design and methods: Fresh urine specimen (n = 48) aliquots in BD Vacutainer® Plus Urinalysis Preservative Tubes and polystyrene tubes were analyzed on an Iris Diagnostics iQ200. Samples in polystyrene tubes were refrigerated for 4 and 8 h Four aliquots in preservative tubes were kept at room temperature for 4, 8, 24, and 72 h, while two aliquots were kept on ice for 4 and 8 h. Results: There was good agreement for all chemistry and microscopy parameters with the exceptions of white blood cells (WBCs) at 24 and 72 h and red blood cells (RBCs) at 72 h. Preservative tubes on ice showed a significant decrease in concordance of WBCs and calcium oxalate (CaOx) parameters compared with the results at room temperature. Results of refrigerated polystyrene tubes showed good agreement with the exceptions of WBC clumps and amorphous crystal at 8 h. Conclusions: A chlorhexidine-containing preservative tube seems advantageous for urine sample transport from outside healthcare services. A preservative tube offers comparable results with urine samples kept in a refrigerator for 4-8 h for the majority of parameters. Keeping samples at room temperature is recommended when preservative tubes are used because ice produces a negative effect on WBCs and CaOx.
Web of Science Eşleşmesi Bulundu
32
WoS Atıf
48
Cilt
Article
Belge Türü
Kaynak: CLINICAL BIOCHEMISTRY
· s. 919-922
Anahtar Kelimeler (WoS)
Havuzumuzdaki Atıflar 0
Bu makaleye, sistemimizdeki Scopus veritabanında bulunan 0 makale atıf yapmıştır. Scopus genel atıf sayısı: 32.
Bu makaleye, kendi Scopus havuzumuzdaki başka bir makaleden atıf kaydı bulunmuyor.
Scimago Dergi Bilgisi
Otomatik ISSN Eşleştirmesi
2015 yılı verileri
Clinical Biochemistry
Q1
SJR Quartile
0,917
SJR Skoru
130
H-Index
Kategoriler: Medicine (miscellaneous) (Q1) · Clinical Biochemistry (Q2)
Alanlar: Biochemistry, Genetics and Molecular Biology · Medicine
Ülke: United States
· Elsevier Inc.
Bu bilgiler makale yılına göre Scimago veritabanından ISSN eşleştirmesiyle otomatik getirilmektedir.
Dergi sıralama verileri Scimago'nun ilgili yılı baz alınmaktadır.
Anahtar Kelimeler
WoS |
Bir kelimeye tıklayıp ilgili kaynaktaki yayınları görün.
Makale Bilgileri
Dergi
Clinical Biochemistry
ISSN
00099120
Yıl
2015
/ 9. ay
Cilt / Sayı
48
/ 13-14
Sayfalar
919 – 922
Makale Türü
Kısa Makale
Hakemlik
Hakemli
Endeks
SCI-Expanded
Yayın Dili
İngilizce
Kapsam
Uluslararası
Toplam Yazar
8 kişi
Erişim Türü
Elektronik
Alan
Sağlık Bilimleri Temel Alanı-
Tıbbi Biyokimya
YÖKSİS Yazar Kaydı
Yazar Adı
ercan müjgan,akbulut emiş deniz,ABUŞOĞLU SEDAT,YILMAZ FATMA MERİÇ,fırat oğuz esra ,topçuoğlu canan,öztekin volkan,boğdaycıoğlu nihal
YÖKSİS ID
514832