Stress analysis of effects of nonrigid connectors on fixed partial dentures with pier abutments
The Journal of Prosthetic Dentistry 2008 Cilt 99 Sayı 3
Scopus Eşleşmesi Bulundu
30
Atıf
99
Cilt
185-192
Sayfa
Özet
Statement of problem.: In some patients, the pattern of missing teeth may require the use of a fixed partial denture (FPD) with an intermediate pier abutment. Information is needed regarding the biomechanical behavior and the position of a nonrigid connector for this treatment option. Purpose.: The purpose of this study was to evaluate, by means of finite element method (FEM), the effects of rigid and nonrigid design types on stress distribution for 5-unit FPDs with pier abutments. Material and methods.: A 3-dimensional cross-section FEM model (SAP 2000) simulating a 5-unit metal ceramic FPD with a pier abutment with rigid or nonrigid designs (connector location at the mesial region of the second molar, at the distal region of the second premolar, at the mesial region of the second premolar, and at the distal region of the canine) was developed. In the model, the canine, second premolar, and second molar served as abutments. A supporting periodontal ligament and alveolar bone (cortical and trabecular) were modeled. A 50-N static vertical occlusal load was applied on the cusp of each abutment to calculate the stress distributions. Three different types of load were evaluated: loading of all cusps to simulate maximum centric occlusion contacts, loading of the canine to simulate a single anterior contact, and loading of the second molar to simulate a posterior contact. Results.: The analysis of the von Mises stress values revealed that maximum stress concentrations were located at the load areas for all models. Also, for all models, the highest stress values were located at connectors and cervical regions of abutment teeth, especially at the pier abutment. Conclusions.: The area of maximum stress concentration at the pier abutment was decreased by the use of a nonrigid connector at the distal region of the second premolar. (J Prosthet Dent 2008;99:185-192). © 2008 The Editorial Council of the Journal of Prosthetic Dentistry.
Web of Science Eşleşmesi Bulundu
27
WoS Atıf
99
Cilt
Article
Belge Türü
Kaynak: JOURNAL OF PROSTHETIC DENTISTRY · s. 185-192

Havuzumuzdaki Atıflar 0

Bu makaleye, sistemimizdeki Scopus veritabanında bulunan 0 makale atıf yapmıştır. Scopus genel atıf sayısı: 30.

Bu makaleye, kendi Scopus havuzumuzdaki başka bir makaleden atıf kaydı bulunmuyor.

Anahtar Kelimeler

Bu makale için anahtar kelime bilgisi bulunmuyor.

Makale Bilgileri

Dergi The Journal of Prosthetic Dentistry
ISSN 00223913
Yıl 2008 / 3. ay
Cilt / Sayı 99 / 3
Sayfalar 185 – 192
Makale Türü Özgün Makale
Hakemlik Hakemli
Endeks SCI
Yayın Dili İngilizce
Kapsam Uluslararası
Toplam Yazar 4 kişi
Erişim Türü Elektronik
Alan Sağlık Bilimleri Temel Alanı- Protetik Diş Tedavisi

YÖKSİS Yazar Kaydı

Yazar Adı ORUÇ MEHMET SELÇUK,ERASLAN OĞUZ,alper tukay,ATAY ARZU
YÖKSİS ID 370700

Metrikler

Scopus Atıf 30
Havuz Atıfları 0
Yazar Sayısı 4