Objective. Wide pulse pressure (PP) affects the accuracy of oscillometric blood pressure measurements (OBPM): however, the degree of this impact on different patient groups with wide PPs is unclear. This study will investigate the accuracy of OBPM in achieving target BP and PP in isolated systolic hypertension (ISH) group compared with mixed hypertension (MHT) group. Method. A total of 115 patients (70 with ISH and 45 with MHT) were enrolled in the study. Upper arm and wrist OBPM, obtained by OmronM3 and OmronR6 devices respectively, were compared with the simultaneously measured values from the ascending aorta. The ISH was defined as a systolic blood pressure (SBP) ≥140 mmHg and a diastolic blood pressure (DBP) <90 mmHg. MHT was defined as a SBP≥140 mmHg and a DBP≥90 mmHg. Results. The mean central arterial blood pressure (BP) and central PP were higher in the ISH group than those in the MHT group. The upper arm OBPM underestimated the central SBP in two groups (-5 mmHg, -3 mmHg, p=0.5, respectively), but overestimated DBP in the ISH group compared with MHT patients (6.8 mmHg, 1 mmHg, p=0.04, respectively). Wrist OBPM similarly underestimated to the central SBP in each group (-16 mmHg, -19 mmHg, p=0.15), whereas the sum of overestimation of DBP was significantly higher in the ISH than in the MHT group (+6 mmHg, - 1 mmHg, p=0.001, respectively). Also, each of the devices underestimated the central PP in the ISH group (about 10 mmHg) as being higher than that of the MHT group. Conclusion. Oscillometric devices may be used for self-BP measurement in patients with ISH without clinically important disadvantages compared with the patients with MHT. For PP measurement in patients with ISH, there were substantial differences between intra-arterial and indirect arm BP measurements. © Informa UK Ltd.
Web of Science Eşleşmesi Bulundu
8
WoS Atıf
19
Cilt
Article
Belge Türü
Kaynak: BLOOD PRESSURE
· s. 98-103
Havuzumuzdaki Atıflar 0
Bu makaleye, sistemimizdeki Scopus veritabanında bulunan 0 makale atıf yapmıştır. Scopus genel atıf sayısı: 9.
Bu makaleye, kendi Scopus havuzumuzdaki başka bir makaleden atıf kaydı bulunmuyor.
Scimago Dergi Bilgisi
Otomatik ISSN Eşleştirmesi
2010 yılı verileri
Blood Pressure
Q2
SJR Quartile
0,510
SJR Skoru
58
H-Index
🔓
Açık Erişim
Kategoriler: Cardiology and Cardiovascular Medicine (Q2) · Internal Medicine (Q2) · Medicine (miscellaneous) (Q2)
Alanlar: Medicine
Ülke: United Kingdom
· Informa Healthcare
Bu bilgiler makale yılına göre Scimago veritabanından ISSN eşleştirmesiyle otomatik getirilmektedir.
Dergi sıralama verileri Scimago'nun ilgili yılı baz alınmaktadır.
Anahtar Kelimeler
Bu makale için anahtar kelime bilgisi bulunmuyor.
Makale Bilgileri
Dergi
Blood Pressure
ISSN
0803-7051
Yıl
2010
/ 4. ay
Cilt / Sayı
19
/ 2
Sayfalar
98 – 103
Makale Türü
Özgün Makale
Hakemlik
Hakemli
Endeks
SCI
Yayın Dili
İngilizce
Kapsam
Uluslararası
Toplam Yazar
10 kişi
Erişim Türü
Elektronik
Alan
Sağlık Bilimleri Temel Alanı-
Kardiyoloji
YÖKSİS Yazar Kaydı
Yazar Adı
Kayrak Mehmet, Ulgen Mehmet S., Yazici Mehmet, Yilmaz Remzi, DEMİR KENAN, Dogan Yildiz, Ozhan Hakan, Alihanoglu Yusuf, Koc Fatih, Bodur Sait