CANLI
Yükleniyor Veriler getiriliyor…
SCI-Expanded Özgün Makale Scopus
Anterior transpedicular screw fixation of cervical spine Is it safe Morphological feasibility technical properties and accuracy of manual insertion
Journal of Neurosurgery: Spine 2015 Cilt 22 Sayı 6
Scopus Eşleşmesi Bulundu
18
Atıf
22
Cilt
596-604
Sayfa
🔓
Açık Erişim
Özet
OBJECT: Due to lack of construct stability of the current anterior cervical approaches, supplemental posterior cervical approaches are frequently employed. The use of an anterior-only approach with anterior transpedicular screws (ATPSs) has been proposed as a means of providing 3-column fixation. This study was designed to investigate the feasibility of anterior transpedicular screw (ATPS) fixation of cervical spine, to obtain the morphological measurements for technical prerequisites, and to evaluate the accuracy of the ATPS using fluoroscopy. METHODS: The study included both radiological and anatomical investigations. The radiological investigations were based on data from cervical spine CT scans performed in 65 patients. Technical prerequisites of ATPS were calculated using OsiriX for Mac OS. In the anatomical part of the study, 30 pedicles (C3-7) from 6 formalin-preserved cadavers were manually instrumented. Measurements obtained included pedicle width (PW), pedicle height (PH), pedicle transverse angle (PTA), distance of the entry point from the midline (DEPM), and distance of the entry point from the superior endplate (DEPSEP). The authors also analyzed screw position in the manually instrumented vertebrae. RESULTS: The mean PW and PH values showed a tendency to increase from C-3 to C-7 in both males and females. The means were significantly larger for both PW and PH in males than in females at all levels (p = 0.001). The overall mean PTA value was significantly lower at C-7 (p < 0.0001). The mean value for the distance of entry point from the midline (DEPM) represented a point at the contralateral side of the pedicle for every level except C-7. The mean DEPSEP values showed significant differences between all levels (p < 0.0001). Seven of the 30 screws were identified as breaching the pedicle (23.3%); these screw malplacements were seen at C-3 (3 screws), C-4 (2 screws), and C-5 (2 screws). CONCLUSIONS: The morphological measurements of this study demonstrated that ATPS fixation is feasible in selected cases. They indicate that ATPS insertion using a fluoroscopy-assisted pedicle axis view is safe at the C-6 and C-7 levels, but the results at the other levels did not prove the safety of this technique.
Web of Science Eşleşmesi Bulundu
16
WoS Atıf
22
Cilt
Article
Belge Türü
Kaynak: JOURNAL OF NEUROSURGERY-SPINE · s. 596-604
Anahtar Kelimeler (WoS)

Havuzumuzdaki Atıflar 0

Bu makaleye, sistemimizdeki Scopus veritabanında bulunan 0 makale atıf yapmıştır. Scopus genel atıf sayısı: 18.

Bu makaleye, kendi Scopus havuzumuzdaki başka bir makaleden atıf kaydı bulunmuyor.
Scimago Dergi Bilgisi Otomatik ISSN Eşleştirmesi 2015 yılı verileri
Journal of Neurosurgery: Spine
Q1
SJR Quartile
1,645
SJR Skoru
127
H-Index
Kategoriler: Medicine (miscellaneous) (Q1) · Neurology (Q1) · Neurology (clinical) (Q1) · Surgery (Q1)
Alanlar: Medicine · Neuroscience
Ülke: United States · American Association of Neurological Surgeons
Bu bilgiler makale yılına göre Scimago veritabanından ISSN eşleştirmesiyle otomatik getirilmektedir. Dergi sıralama verileri Scimago'nun ilgili yılı baz alınmaktadır.

Anahtar Kelimeler

WoS | Bir kelimeye tıklayıp ilgili kaynaktaki yayınları görün.

Makale Bilgileri

Dergi Journal of Neurosurgery: Spine
ISSN 1547-5654
Yıl 2015 / 6. ay
Cilt / Sayı 22 / 6
Sayfalar 596 – 604
Makale Türü Özgün Makale
Hakemlik Hakemli
Endeks SCI-Expanded
Yayın Dili İngilizce
Kapsam Uluslararası
Toplam Yazar 6 kişi
Erişim Türü Elektronik
Alan Sağlık Bilimleri Temel Alanı- Nöroşirurji

YÖKSİS Yazar Kaydı

Yazar Adı KÖKTEKİR ENDER,Toktaş Orkun Zafer,ŞEKER AŞKIN,AKAKIN AKIN,KONYA DENİZ,KILIÇ TÜRKER
YÖKSİS ID 673896

Metrikler

Scopus Atıf 18
Havuz Atıfları 0
Yazar Sayısı 6