Scopus Eşleşmesi Bulundu
7
Atıf
101
Cilt
Özet
The aim of this study was to quantitatively evaluate out-of-field (peripheral) doses in electron beam radiotherapy, to compare experimental measurements with treatment planning system (TPS) calculations and Monte Carlo (MC) simulations, and to discuss their clinical relevance. Peripheral dose measurements were performed in a water phantom using a Roos parallel-plate ionization chamber for 6, 9, 12, and 15 MeV electron beams delivered by a Varian linear accelerator with various applicator sizes. Under identical conditions, dose distributions were recalculated with the Eclipse TPS using the General Gaussian Pencil Beam (GGPB) algorithm and with Geant4/GATE MC simulations. The dependence of peripheral dose on energy, applicator size, and distance from the field edge was assessed. Experimental data showed that peripheral doses increased with both beam energy and applicator size, while decreasing with greater depth and distance from the field border. TPS calculations consistently underestimated peripheral doses, with discrepancies up to 30% at higher energies and near-field regions. By contrast, MC simulations demonstrated excellent agreement with measurements across all energies and field sizes, with differences typically within 1%–2%. The results demonstrate that the GGPB algorithm tested in this study substantially underestimates out-of-field doses. Experimental dosimetry and validated MC simulations are essential for comprehensive dose evaluation, particularly for estimating secondary cancer risks, protecting adjacent critical organs, and ensuring the safety of implantable devices. The integration of GPU-accelerated Monte Carlo algorithms and AI-based prediction models into clinical workflows may further improve the accuracy and efficiency of peripheral dose calculations, ultimately enhancing patient safety.
Web of Science Eşleşmesi Bulundu
7
WoS Atıf
101
Cilt
Article
Belge Türü
Kaynak: PHYSICA SCRIPTA
Anahtar Kelimeler (WoS)
Havuzumuzdaki Atıflar 0
Bu makaleye, sistemimizdeki Scopus veritabanında bulunan 0 makale atıf yapmıştır. Scopus genel atıf sayısı: 7.
Bu makaleye, kendi Scopus havuzumuzdaki başka bir makaleden atıf kaydı bulunmuyor.
Anahtar Kelimeler
electron beam radiotherapy
out-of-field dose
roos ionization chamber
treatment planning system
Monte Carlo simulation
WoS |
Bir kelimeye tıklayıp ilgili kaynaktaki yayınları görün.
Makale Bilgileri
Dergi
Physica Scripta
ISSN
0031-8949
Yıl
2026
/ 1. ay
Makale Türü
Özgün Makale
Hakemlik
Hakemli
Endeks
SCI-Expanded
JCR Quartile
Q2
Yayın Dili
İngilizce
Kapsam
Uluslararası
Toplam Yazar
2 kişi
Erişim Türü
Basılı+Elektronik
Alan
Sağlık Bilimleri Temel Alanı
Sağlık Fiziği
YÖKSİS Yazar Kaydı
Yazar Adı
GÜL OSMAN VEFA,ŞAHMARAN TURAN
YÖKSİS ID
9331112