CANLI
Yükleniyor Veriler getiriliyor…
SCI-Expanded JCR Q4 Özgün Makale Scopus
Evaluation of the Thyroid Parenchymal Stiffness During Pregnancy Using Two-Dimensional Shear Wave Elastography: A Longitudinal Prospective Study
Iranian Journal of Radiology 2025 Cilt 22
Scopus Eşleşmesi Bulundu
0
Atıf
22
Cilt
🔓
Açık Erişim
Özet
Background: During pregnancy, numerous changes occur in thyroid gland functions. Ultrasonography (US) is one of the primary imaging methods used for thyroid gland examination. Two-dimensional shear wave elastography (2D-SWE) is an imaging method that allows the quantitative evaluation of the stiffness of tissues, and its use in thyroid gland diseases is gradually increasing. Objectives: The present study aimed to investigate whether there are changes in thyroid parenchymal stiffness during pregnancy and to determine normal 2D-SWE values of the thyroid gland in each trimester. Patients and Methods: Forty-eight healthy pregnant women were evaluated. The dimensions of thyroid lobes were measured separately, and volume values were calculated. The 2D-SWE measurements were made by drawing a circular region of interest (ROI) in the axial plane for both thyroid lobes. Results: The mean age was 28.4 ± 6.0 years. The mean elasticity values (kPa) for the three trimesters were 8.77 ± 1, 8.1 ± 0.7, and 7.6 ± 0.7. Mean velocity values (m/s) were 1.71 ± 0.1, 1.64 ± 0.08, and 1.60 ± 0.07. Total thyroid volume values (mL) were 9.72 ± 4.21, 10.69 ± 4.55, and 11.75 ± 5.2. The 2D-SWE elasticity and velocity values significantly decreased across trimesters (P < 0.05), whereas thyroid volume showed a non-significant trend toward increase. Conclusion: Our study is one of the few longitudinal prospective studies in the literature in which the thyroid gland was evaluated sonographically in pregnant women. We quantitatively demonstrated, with objective numerical data, a significant decrease in thyroid elastography values during pregnancy, while thyroid volume exhibited a non-significant tendency to increase.
Web of Science Eşleşmesi Bulundu
0
WoS Atıf
22
Cilt
Article
Belge Türü
Kaynak: IRANIAN JOURNAL OF RADIOLOGY
Anahtar Kelimeler (WoS)

Havuzumuzdaki Atıflar 0

Bu makaleye, sistemimizdeki Scopus veritabanında bulunan 0 makale atıf yapmıştır.

Bu makaleye, kendi Scopus havuzumuzdaki başka bir makaleden atıf kaydı bulunmuyor.
Scimago Dergi Bilgisi Otomatik ISSN Eşleştirmesi 2025 yılı verileri
Iranian Journal of Radiology
Q4
SJR Quartile
0,150
SJR Skoru
25
H-Index
🔓
Açık Erişim
Kategoriler: Radiology, Nuclear Medicine and Imaging (Q4)
Alanlar: Medicine
Ülke: Netherlands · Brieflands
Bu bilgiler makale yılına göre Scimago veritabanından ISSN eşleştirmesiyle otomatik getirilmektedir. Dergi sıralama verileri Scimago'nun ilgili yılı baz alınmaktadır.

Anahtar Kelimeler

WoS | Bir kelimeye tıklayıp ilgili kaynaktaki yayınları görün.

Makale Bilgileri

Dergi Iranian Journal of Radiology
ISSN 1735-1065
Yıl 2025 / 4. ay
Cilt / Sayı 22
Makale Türü Özgün Makale
Hakemlik Hakemli
Endeks SCI-Expanded
JCR Quartile Q4
Teşvik Puanı 0,56 · YÖKSİS Akademik Teşvik
Yayın Dili Türkçe
Kapsam Uluslararası
Toplam Yazar 8 kişi
Erişim Türü Basılı+Elektronik
Alan Sağlık Bilimleri Temel Alanı Radyoloji

YÖKSİS Yazar Kaydı

Yazar Adı TOPALOĞLU ÖMER FARUK,ATEŞ FATİH,DURMAZ MEHMET SEDAT,SEÇİLMİŞ ÖZLEM,GÖKGÖZ DURMAZ FUNDA,AKTAŞ GÖRKEM,ÖZLER GÜMÜŞ SİBEL,KOPLAY MUSTAFA
YÖKSİS ID 9297819

Metrikler

Havuz Atıfları 0
JCR Quartile Q4
Teşvik Puanı 0,56
Yazar Sayısı 8