Kurumun Atıf Alan Makalesi
Atıf Alan Yayın
Direct electron transfer from glucose oxidase immobilized on polyphenanthroline-modified glassy carbon electrode
Scopus
Toplam 120 atıf DOI
This study reports direct electron transfer (DET) from immobilized glucose oxidase (GOx) via grafted and electropolymerized 1,10-phenanthroline monohydrate (PMH). The layer of poly-1,10-phenanthroline (PPMH) was gained via electrochemical deposition, which was used to create the PPMH-modified GC-electrode (PPMH/GC-electrode). Further, the GOx was immobilized on the PPMH/GC-electrode. The effect of surface-modification by the PPMH on the electron-transfer between enzyme and electrode-surface and some other electrochemical/analytical-parameters of newly designed enzymatic-electrode were evaluated. The PPMH/GC-electrode showed superior DET to/from flavine adenine dinucleotide cofactor of GOx, while some redox-compounds including ferrocene and K3[Fe(CN)6] were completely electrochemically inactive on the PPMH/GC-electrode. It was also found that the resulting GOx/PPMH/GC-electrode functioned as a " direct response type" glucose-biosensor. The biosensor showed excellent selectivity towards glucose and demonstrated good operational-stability. According to our best knowledge, this study is the first scientific report on electrochemical-polymerization of PMH on the GC-electrode in non-aqueous media followed by its application in the design of glucose-biosensor. © 2010 Elsevier B.V.
Atıf Kaynağı
Atıf Yapan Yayın
Electrochemical copper (II) sensor based on self-assembled 4-amino-6-hydroxy-2-mercaptopyrimidine monohydrate
Scopus
Havuzumuzda 32 atıf almış
A 4-amino-6-hydroxy-2-mercaptopyrimidine monohydrate (AHMP)-based self-assembled monolayer (SAM) was formed on the gold electrode surface. Ellipsometric measurements evidenced the SAM formation on the gold electrode surface. The structural integrity of the modified gold electrode was also characterized by insulating properties of the SAM that were detected by cyclic voltammetry. The results of cyclic voltammetry showed that the SAM, which was formed by assembly of AHMP, was stable but did not completely block the redox-activity of ferrocene and K3[Fe(CN)6]/K 4[Fe(CN)6]. In contrast completely blocked redox-activity was observed after the treatment of AHMP-based SAM with saturated solution of 4-formylphenylboronic acid in 1,4-dioxan. The modified electrodes exhibited a selective response towards Cu(II) ions in the presence of some interfering ions such as Cd(II), Co(II), Fe(II), Ni(II) and Pb(II). This study is the first scientific report on the application of AHMP-modified electrode as a selective Cu(II) sensor in the presence of some interfering cations. © 2011 Elsevier B.V. All rights reserved.
Atıf Yapan Makale Bilgileri
Kurumlar (2)
Selçuk Üniversitesi
Selçuklu, Turkey
Vilniaus Universitetas
Vilnius, Lithuania