Direct electron transfer from glucose oxidase immobilized on polyphenanthroline-modified glassy carbon electrode
Scopus
Toplam 120 atıf DOI
This study reports direct electron transfer (DET) from immobilized glucose oxidase (GOx) via grafted and electropolymerized 1,10-phenanthroline monohydrate (PMH). The layer of poly-1,10-phenanthroline (PPMH) was gained via electrochemical deposition, which was used to create the PPMH-modified GC-electrode (PPMH/GC-electrode). Further, the GOx was immobilized on the PPMH/GC-electrode. The effect of surface-modification by the PPMH on the electron-transfer between enzyme and electrode-surface and some other electrochemical/analytical-parameters of newly designed enzymatic-electrode were evaluated. The PPMH/GC-electrode showed superior DET to/from flavine adenine dinucleotide cofactor of GOx, while some redox-compounds including ferrocene and K3[Fe(CN)6] were completely electrochemically inactive on the PPMH/GC-electrode. It was also found that the resulting GOx/PPMH/GC-electrode functioned as a " direct response type" glucose-biosensor. The biosensor showed excellent selectivity towards glucose and demonstrated good operational-stability. According to our best knowledge, this study is the first scientific report on electrochemical-polymerization of PMH on the GC-electrode in non-aqueous media followed by its application in the design of glucose-biosensor. © 2010 Elsevier B.V.
Atıf Kaynağı
Atıf Yapan Yayın
Phenanthroline derivatives electrochemically grafted to glassy carbon for Cu(II) ion detection
Scopus
Havuzumuzda 39 atıf almış
New sensing platform based on modified glassy carbon (GC) suitable for design of heavy metal-ion sensor is reported in this study. GC-based electrodes were electrochemically modified by poly-5-nitro-1,10-phenanthroline (poly-5NP) and poly-5-amino, 6-nitro-1,10-phenanthroline (poly-5A6NP) layers. Grafting of electrochemically formed poly-5NP and poly-5A6NP layers at the GC electrode surface was confirmed by electrochemical reduction of nitro groups into amine groups. Presence of grafted poly-5NP and poly-5A6NP layers and formation of their reduced forms on the GC electrode surface were verified by cyclic voltammetry, electrochemical impedance spectroscopy, contact angle measurements, ellipsometry and X-ray photoelectron spectroscopy. The applicability of poly-5NP- and poly-5A6NP-functionalized carbon surfaces for the determination of Cu(II) ions was demonstrated by formation of complexes between GC-grafted poly-5NP and poly-5A6NP layers and Cu(II) ions. © 2012 Elsevier B.V. All rights reserved.
Atıf Yapan Makale Bilgileri
Kurumlar (5)
Ankara Üniversitesi
Ankara, Turkey
Dumlupinar Üniversitesi
Kutahya, Turkey
Kyrgyz-Turkish Manas University
Bishkek, Kyrgyzstan
Selçuk Üniversitesi
Selçuklu, Turkey
Vilniaus Universitetas
Vilnius, Lithuania