CANLI
Yükleniyor Veriler getiriliyor…
/ Atıflar / Detay

Atıf Detayı

Kurum makalesi · Scopus üzerinden alınan atıf kaydı

Kurumun Atıf Alan Makalesi
Atıf Alan Yayın
Direct electron transfer from glucose oxidase immobilized on polyphenanthroline-modified glassy carbon electrode
Biosensors and Bioelectronics Cilt 26 ss. 2541-2546
Scopus Toplam 120 atıf DOI
This study reports direct electron transfer (DET) from immobilized glucose oxidase (GOx) via grafted and electropolymerized 1,10-phenanthroline monohydrate (PMH). The layer of poly-1,10-phenanthroline (PPMH) was gained via electrochemical deposition, which was used to create the PPMH-modified GC-electrode (PPMH/GC-electrode). Further, the GOx was immobilized on the PPMH/GC-electrode. The effect of surface-modification by the PPMH on the electron-transfer between enzyme and electrode-surface and some other electrochemical/analytical-parameters of newly designed enzymatic-electrode were evaluated. The PPMH/GC-electrode showed superior DET to/from flavine adenine dinucleotide cofactor of GOx, while some redox-compounds including ferrocene and K3[Fe(CN)6] were completely electrochemically inactive on the PPMH/GC-electrode. It was also found that the resulting GOx/PPMH/GC-electrode functioned as a " direct response type" glucose-biosensor. The biosensor showed excellent selectivity towards glucose and demonstrated good operational-stability. According to our best knowledge, this study is the first scientific report on electrochemical-polymerization of PMH on the GC-electrode in non-aqueous media followed by its application in the design of glucose-biosensor. © 2010 Elsevier B.V.
Atıf Kaynağı
Atıf Yapan Yayın
Biofuel cell based on anode and cathode modified by glucose oxidase
Electroanalysis Cilt 25 ss. 2677-2683
Scopus Havuzumuzda 56 atıf almış
A single compartment biofuel cell (BFC) based on an anode and a cathode powered by the same fuel glucose is reported. Glucose oxidase (GOx) from Aspergillus niger was applied as a glucose consuming biocatalyst for both anode and cathode of the BFC. The 5-amino-1,10-phenanthroline modified graphite rod electrode (GRE) with cross-linked GOx was used as the bioanode, and the GRE with co-immobilised horseradish peroxidase and GOx was exploited as the biocathode of the BFC. The open-circuit voltage of the designed BFC exceeded 450mV and a maximal power density of 3.5μW/cm2 was registered at a cell voltage of 300mV. © 2013 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.
Atıf Yapan Makale Bilgileri
Kurumlar (4)
Ankara Üniversitesi Ankara, Turkey
Kyrgyz-Turkish Manas University Bishkek, Kyrgyzstan
Selçuk Üniversitesi Selçuklu, Turkey
Vilniaus Universitetas Vilnius, Lithuania