Kurumun Atıf Alan Makalesi
Atıf Alan Yayın
On-site and low-cost detection of cyanide by simple colorimetric and fluorogenic sensors: Smartphone and test strip applications
Scopus
Toplam 131 atıf DOI
Cyanide is potentially hazardous and quickly acting chemical used in many fields of industry. Therefore, detection of cyanide is of main health concern due to its serious impacts on living organisms. In this context, we have developed rapid, low-cost and on-site sensory two molecules for the colorimetric and fluorogenic sensing of cyanide ion in aqueous samples and food samples. The prepared probes undergo distinct visual color change and exhibits selective fluorogenic turn-on or turn-off response towards cyanide. Competing anions have little or negligible effect on the detection of cyanide. The limit of detection for cyanide ion was calculated as low as 0.45 μM. Free receptors could be successfully regenerated by treating them with Ag+ ion. Moreover, a new visual colorimetric strip based on paper was fabricated with the pale yellow-to-pink color change signal. The fabricated test strips also demonstrated excellent selectivity towards cyanide ion without interfering possible fluoride and acetate ions. The smartphone-based technique which could directly read out the color value using a smartphone revealed an excellent potential for the cyanide detection without additional device.
Atıf Kaynağı
Atıf Yapan Yayın
Ratiometric detection and monitoring of cyanide in biological, environmental and food samples by a novel triphenylamine-xhantane based fluorescent probe
Scopus
Havuzumuzda 13 atıf almış
Background: As cyanide (CN−) is a significant hazard to the environment and human health, it is essential to monitor cyanide levels in water and food samples. Moreover, real-time visualization of CN−could provide an additional understanding of its critical physiological and toxicological roles in living cells. The fluorescence approach based on small organic probes is an effective way for the detection of CN−. In this approach, a triphenylamine-xhantane conjugate was applied to detect in many samples such as sewage water, soil, sprouted potato, apricot seed, and living cells. Results: We report a new ratiometric near-infrared fluorescent probe based on a triphenylamine-xhantane derivative for CN−sensing in many samples. The probe displays high selectivity for only CN− ions among a series of analytes. The addition of cyanide to the dicyanovinyl moiety of the probe disrupts π-conjugation followed by the interruption of internal charge transfer. Consequently, the emission peak of the probe shifts hypsochromically from 655 to 495 nm. There is a linear correlation between the emission intensity (I495) and cyanide level, with a detection limit of 0.036 μM. The probe has many advantages over many probes, such as NIR fluorescence, ratiometric response, low cytotoxicity (85.0 % cell viability up to 50.0 μM of the probe), good membrane permeability, fast response time (4.0 min), high selectivity, good photostability, and anti-interference capability. Significance: Although various probes have been reported in the literature, the use of triphenylamine-xhantane unit as CN− probe has yet to be explored. The probe can detect trace levels of cyanide in many samples such as sewage water, soil, sprouted potatoes, and apricot seeds. Furthermore, it is successfully utilized for the ratiometric fluorescent bioimaging of cyanide in living cells.
Atıf Yapan Makale Bilgileri
Kurumlar (2)
Giresun Üniversitesi
Giresun, Turkey
Selçuk Üniversitesi
Selçuklu, Turkey