CANLI
Yükleniyor Veriler getiriliyor…
/ Atıflar / Detay

Atıf Detayı

Kurum makalesi · Scopus üzerinden alınan atıf kaydı

Kurumun Atıf Alan Makalesi
Atıf Alan Yayın
A new electrochemical sensor based on Fe3O4 functionalized graphene oxide-gold nanoparticle composite film for simultaneous determination of catechol and hydroquinone
Electrochimica Acta Cilt 186 ss. 302-313
Scopus Toplam 238 atıf DOI
Catechol (1,2-dihydroxybenzene) and hydroquinone (1,4-dihydroxybenzene) are two isomers of phenolic compounds which often coexist and interfere with each other during their identification in environmental samples. This study presents simultaneous determination of catechol (CC) and hydroquinone (HQ) using a new electrochemical sensor based on Fe3O4 functionalized graphene oxide-gold nanoparticle composite (AuNPs/Fe3O4-APTES-GO). CV results show well-defined oxidation peaks with anodic peaks at 0.15 V for CC and 0.05 V for HQ, and the peak-to-peak separation for CC and HQ is about 100 mV. Under the optimized conditions, the current response of AuNPs/Fe3O4-APTES-GO/GCE is linear for CC and HQ in the range of 2-145 μM and 3-137 μM, respectively. The detection limits for CC and HQ were found to be 0.8 μM and 1.1 μM, respectively. The fabricated sensor was successfully applied for the determination of CC and HQ in tap water sample with satisfactory recovery.
Atıf Kaynağı
Atıf Yapan Yayın
Electrochemical Detection of Epinephrine Based on a Screen-printed Electrode Modified with NiO−ERGO Nanocomposite Film
Electroanalysis Cilt 33 ss. 2460-2468
Scopus Havuzumuzda 19 atıf almış
This study presents a new electrochemical sensor (NiO−ERGO/SPE) for sensitive and selective detection of epinephrine (EPI) on the screen-printed electrode (SPE) which is modified with a nanocomposite film consisting of electrochemically reduced graphene oxide and NiO nanoparticles. After surface functionalization, structural and electrochemical characterization of NiO−ERGO film, DPV signals of NiO−ERGO/SPE towards the oxidation of EPI exhibited a linear correlation in the concentration range of 0.025 μM to 175 μM with a detection limit of 0.015 μM, which reveals NiO−ERGO film is manifested a good electrocatalytic activity for EPI detection compared with the previous reports. The selectivity of NiO−ERGO film was also tested on a very wide scale of possible interferents (ascorbic acid, uric acid, dopamine, lactic acid, phenylalanine, tyrosine, tryptophan, Li+, Na+, K+, Ca2+, and Zn2+). Moreover, to evaluate the applicability of the proposed sensor for real sample analysis, NiO−ERGO/SPE was successfully utilized for the determination of EPI in pharmaceutical samples.
Atıf Yapan Makale Bilgileri
Kurumlar (2)
Karamanoğlu Mehmetbey Üniversitesi Karaman, Turkey
Selçuk Üniversitesi Selçuklu, Turkey