A new electrochemical sensor based on Fe3O4 functionalized graphene oxide-gold nanoparticle composite film for simultaneous determination of catechol and hydroquinone
Scopus
Toplam 238 atıf DOI
Catechol (1,2-dihydroxybenzene) and hydroquinone (1,4-dihydroxybenzene) are two isomers of phenolic compounds which often coexist and interfere with each other during their identification in environmental samples. This study presents simultaneous determination of catechol (CC) and hydroquinone (HQ) using a new electrochemical sensor based on Fe3O4 functionalized graphene oxide-gold nanoparticle composite (AuNPs/Fe3O4-APTES-GO). CV results show well-defined oxidation peaks with anodic peaks at 0.15 V for CC and 0.05 V for HQ, and the peak-to-peak separation for CC and HQ is about 100 mV. Under the optimized conditions, the current response of AuNPs/Fe3O4-APTES-GO/GCE is linear for CC and HQ in the range of 2-145 μM and 3-137 μM, respectively. The detection limits for CC and HQ were found to be 0.8 μM and 1.1 μM, respectively. The fabricated sensor was successfully applied for the determination of CC and HQ in tap water sample with satisfactory recovery.
Atıf Kaynağı
Atıf Yapan Yayın
A lab-made screen-printed sensing strip for sensitive and selective electrochemical detection of butylated hydroxyanisole
Scopus
Havuzumuzda 19 atıf almış
This study describes the fabrication of a lab-made screen-printed electrode (LabSPE) and its sensing ability for the detection of butylated hydroxyanisole (BHA) which is a synthetic antioxidant utilized widely in food industries. The lab-made screen-printed electrodes were printed on a polycarbonate substrate stepwise via a screen-printing technique using various inks suitable for electrode templates and then modified for the detection of BHA. As for the design of the sensor, firstly, graphitic carbon nitride (g-C3N4) was synthesized electrochemically through the one-pot synthesis method. After the synthesis of Fe3O4 nanoparticles (Fe3O4 NPs), the surface of SPE was modified with the dual composite consisting of g-C3N4 and Fe3O4 NPs. Lastly, platinum nanoparticles (Pt NPs) were deposited electrochemically on the modified electrode in 0.5 M HCl solution containing 2 mM H2PtCl6 at a constant potential of 0.25 V for 45 s. After optimization of varied parameters such as pH of the electrolyte solution, deposition time, and deposition potential, the current responses of the sensor (Pt/g-C3N4-Fe3O4/LabSPE) toward BHA displayed linearity in the wide concentration range of 0.25 μM to 90 μM with a low detection limit of 0.053 μM. The selectivity of Pt/g-C3N4-Fe3O4/SPE was tested successfully in the presence of other antioxidants (BHT, TBHQ, GA, and PG). Moreover, the applicability of the proposed sensor for practical tests was verified by the detection of BHA in commercial samples.
Atıf Yapan Makale Bilgileri
Kurumlar (1)
Selçuk Üniversitesi
Selçuklu, Turkey